Enxerto dermoadiposo em cavidades anoftálmicas secundárias - estudo retrospectivo e revisão da literatura

dc.contributor.authorNarikawa, Silvia [UNESP]
dc.contributor.authorSchellini, Silvana Artioli [UNESP]
dc.contributor.authorPadovani, Carlos Roberto [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T13:36:40Z
dc.date.available2014-05-20T13:36:40Z
dc.date.issued2011-11-01
dc.description.abstractPurpose: To evaluate the dermofat graft in the anophthalmic socket treatment. Methods: A retrospective study including 28 anophthalmic cavity carriers treated with dermofat graft was carried out. The patients were analyzed according to age, sex, socket contraction degree, first surgery performed, reason for graft choice, procedure's results and complications. The data were analyzed according to the frequency of occurrence. Results: Nineteen (67.8%) of the 28 analyzed patients were male. According to age the majority of patients were between 40 to 60 years old (13 patients - 46.4%) and the most common cause of eyeball loss was trauma (seven cases - 25%). Anophthalmic socket type III was the most frequently observed (32.1%). The evisceration was the first procedure in 13 cases, enucleation in 11 and skin graft was done in two patients. Two patients came to the service after evisceration and did not provide any information about the first surgery. The choice to use the dermofat graft was to replace volume at the socket of 12 patients (42.8%). Most of the patients (53.6%) had no complications and graft necrosis was the problem most frequently observed (32.1%). The surgery was considered good in 71.4% and not good in only 7.1%. Conclusion: the dermofat graft is an efficient and easy technique to reconstruct the anophthalmic cavity. The authors suggest this procedure must be introduced in the medical training services since it provide good results.en
dc.description.affiliationUniv Estadual Julio de Mesquita Filho, Fac Med Botucatu, Dept OFT ORL CCP, UNESP, BR-18618000 Botucatu, SP, Brazil
dc.description.affiliationUnespUniv Estadual Julio de Mesquita Filho, Fac Med Botucatu, Dept OFT ORL CCP, UNESP, BR-18618000 Botucatu, SP, Brazil
dc.format.extent411-415
dc.identifierhttp://dx.doi.org/10.1590/S0034-72802011000600015
dc.identifier.citationRevista Brasileira de Oftalmologia. Rio de Janeiro: Soc Brasileira Oftalmologia, v. 70, n. 6, p. 411-415, 2011.
dc.identifier.doi10.1590/S0034-72802011000600015
dc.identifier.fileS0034-72802011000600015.pdf
dc.identifier.issn0034-7280
dc.identifier.lattes9420249100835492
dc.identifier.scieloS0034-72802011000600015
dc.identifier.urihttp://hdl.handle.net/11449/12615
dc.identifier.wosWOS:000300059700015
dc.language.isopor
dc.publisherSoc Brasileira Oftalmologia
dc.relation.ispartofRevista Brasileira de Oftalmologia
dc.relation.ispartofsjr0,147
dc.rights.accessRightsAcesso aberto
dc.sourceWeb of Science
dc.subjectAnophthalmos/surgeryen
dc.subjectOrbital implants/methodsen
dc.subjectReconstructive surgery proceduresen
dc.subjectAdipose tissue/transplantationen
dc.titleEnxerto dermoadiposo em cavidades anoftálmicas secundárias - estudo retrospectivo e revisão da literaturapt
dc.title.alternativeEnxerto dermoadiposo em cavidades anoftálmicas secundárias - estudo retrospectivo e revisão da literaturapt
dc.title.alternativeDermofat graft in secondary anophthalmic socket - a retrospective study and literature reviewen
dc.typeArtigo
dcterms.rightsHolderSoc Brasileira Oftalmologia
unesp.author.lattes9420249100835492
unesp.author.lattes8727897080522289[3]
unesp.author.orcid0000-0002-6938-1230[2]
unesp.author.orcid0000-0002-7719-9682[3]
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Medicina, Botucatupt
unesp.departmentOftalmologia, Otorrinolaringologia e Cirurgia de Cabeça e Pescoço - FMBpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S0034-72802011000600015.pdf
Tamanho:
111.74 KB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: