Carbamide Peroxide Determination in Tooth Whitening Using a Reagentless HRP-Biosensor

dc.contributor.authorVidal, Isabelle Goncalves
dc.contributor.authorTescarollo Dias, Iara Lucia
dc.contributor.authorde Oliveira Neto, Graciliano
dc.contributor.authorde Vasconcellos Lanza, Marcos Roberto
dc.contributor.authorTaboada Sotomayor, Maria Del Pilar [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniv Sao Francisco
dc.contributor.institutionCity Dept Educ
dc.date.accessioned2014-05-20T15:32:30Z
dc.date.available2014-05-20T15:32:30Z
dc.date.issued2009-01-01
dc.description.abstractA rapid and effective method for carbamide peroxide (CP) quantification in pharmaceuticals is proposed. The reagentless biosensor was prepared by using lyophilized turnip extract as horseradish peroxidase (HRP) enzyme source. The biosensor presented the best performance. The measurements were carried out in 0.1mol L-1 Pipes buffer (pH 6.0). At-100mV vs. Ag|AgCl, a linear response range from 3.0 to 25.0mmol L-1 was obtained. The quantification and detection limits were 1.2 and 0.4mmol L-1, respectively, and the response time was 0.5s. The biosensor repeatability, storage, and lifetime were excellent, allowing a satisfactory CP quantification in real pharmaceutical samples, when compared with those obtained by the official method.en
dc.description.affiliationSão Paulo State Univ, Inst Chem, BR-14800900 Araraquara, SP, Brazil
dc.description.affiliationUniv Sao Francisco, BR-12900000 Braganca Paulista, SP, Brazil
dc.description.affiliationCity Dept Educ, Campinas, SP, Brazil
dc.description.affiliationUnespSão Paulo State Univ, Inst Chem, BR-14800900 Araraquara, SP, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipIdCNPq: 470025/2006-9
dc.format.extent352-365
dc.identifierhttp://dx.doi.org/10.1080/00032710802507927
dc.identifier.citationAnalytical Letters. Philadelphia: Taylor & Francis Inc, v. 42, n. 2, p. 352-365, 2009.
dc.identifier.doi10.1080/00032710802507927
dc.identifier.issn0003-2719
dc.identifier.urihttp://hdl.handle.net/11449/41385
dc.identifier.wosWOS:000263553400013
dc.language.isoeng
dc.publisherTaylor & Francis Inc
dc.relation.ispartofAnalytical Letters
dc.relation.ispartofjcr1.206
dc.relation.ispartofsjr0,344
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectAmperometric biosensoren
dc.subjectbrassica napus Len
dc.subjectcarbamide peroxideen
dc.subjectHRPen
dc.subjectlyophilization procedureen
dc.titleCarbamide Peroxide Determination in Tooth Whitening Using a Reagentless HRP-Biosensoren
dc.typeArtigo
dcterms.licensehttp://journalauthors.tandf.co.uk/permissions/reusingOwnWork.asp
dcterms.rightsHolderTaylor & Francis Inc
unesp.campusUniversidade Estadual Paulista (Unesp), Instituto de Química, Araraquarapt
unesp.departmentQuímica Analítica - IQARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: