Flexural strength and hardness of reline and denture base acrylic resins after different exposure times of microwave disinfection
dc.contributor.author | Ribeiro, Daniela Garcia [UNESP] | |
dc.contributor.author | Pavarina, Ana Cláudia [UNESP] | |
dc.contributor.author | Machado, Ana Lucia [UNESP] | |
dc.contributor.author | Giampaolo, Eunice Teresinha [UNESP] | |
dc.contributor.author | Vergani, Carlos Eduardo [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | |
dc.date.accessioned | 2022-04-29T08:47:48Z | |
dc.date.available | 2022-04-29T08:47:48Z | |
dc.date.issued | 2008-11-01 | |
dc.description.abstract | Objectives: To evaluate the effect of microwave disinfection on the flexural strength and Vickers hardness of 4 autopolymerized resins (Kooliner [K], Tokuso Rebase Fast [T], Ufi Gel Hard [U], and New Truliner [N]) and 1 denture base resin (Lucitone 550 [L]). Method and Materials: For each material, 48 specimens (64 × 10 × 3.3 mm) were made and divided into 6 equal groups (n = 8). In the control group, specimens were untreated. Before testing, specimens were immersed in 200 mL of distilled water and submitted to disinfection for 1 of the following irradiation times: 1, 2, 3, 4, or 5 minutes. The irradiation procedure was performed twice. The flexural strength was determined using a testing machine MTS-810 and measurements of Vickers hardness were made on Micromet 2100. The values were submitted to ANOVA and Tukey's test (P = .05). Results: The K material showed a significant increase (P = .0010) in flexural strength following 5 minutes of disinfection compared to control specimens. The flexural strength mean values of materials T, U, and N were not significantly affected (P > .05) by disinfection. Compared to the control group, the K material showed a significant increase in hardness (P < .001) following disinfection for 3, 4, and 5 minutes. For material U, disinfection for 4 and 5 minutes produced specimens with significantly increased hardness values (P < .001) compared to the control group. For material N, disinfection for 5 minutes resulted in significantly higher hardness values (P < .001) than the control group. Conclusion: Regardless of the irradiation time, the flexural strength and hardness of the materials evaluated were not detrimentally affected by microwave disinfection. | en |
dc.description.affiliation | Department of Dental Materials and Prosthodontics São Paulo State University UNESP, São Paulo | |
dc.description.affiliation | Faculdade de Odontologia de Araraquara - UNESP, Rua Humaitá, no. 1680, Araraquara, São Paulo, C.E.P.: 14801-903 | |
dc.description.affiliationUnesp | Department of Dental Materials and Prosthodontics São Paulo State University UNESP, São Paulo | |
dc.description.affiliationUnesp | Faculdade de Odontologia de Araraquara - UNESP, Rua Humaitá, no. 1680, Araraquara, São Paulo, C.E.P.: 14801-903 | |
dc.format.extent | 833-840 | |
dc.identifier.citation | Quintessence International, v. 39, n. 10, p. 833-840, 2008. | |
dc.identifier.issn | 0033-6572 | |
dc.identifier.scopus | 2-s2.0-54449094716 | |
dc.identifier.uri | http://hdl.handle.net/11449/231851 | |
dc.language.iso | eng | |
dc.relation.ispartof | Quintessence International | |
dc.source | Scopus | |
dc.subject | Acrylic resins | |
dc.subject | Cross infection | |
dc.subject | Disinfection | |
dc.subject | Flexural strength | |
dc.subject | Hardness | |
dc.subject | Microwave | |
dc.title | Flexural strength and hardness of reline and denture base acrylic resins after different exposure times of microwave disinfection | en |
dc.type | Artigo | |
unesp.campus | Universidade Estadual Paulista (Unesp), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Materiais Odontológicos e Prótese - FOAR | pt |