Flexural strength and hardness of reline and denture base acrylic resins after different exposure times of microwave disinfection

dc.contributor.authorRibeiro, Daniela Garcia [UNESP]
dc.contributor.authorPavarina, Ana Cláudia [UNESP]
dc.contributor.authorMachado, Ana Lucia [UNESP]
dc.contributor.authorGiampaolo, Eunice Teresinha [UNESP]
dc.contributor.authorVergani, Carlos Eduardo [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.date.accessioned2022-04-29T08:47:48Z
dc.date.available2022-04-29T08:47:48Z
dc.date.issued2008-11-01
dc.description.abstractObjectives: To evaluate the effect of microwave disinfection on the flexural strength and Vickers hardness of 4 autopolymerized resins (Kooliner [K], Tokuso Rebase Fast [T], Ufi Gel Hard [U], and New Truliner [N]) and 1 denture base resin (Lucitone 550 [L]). Method and Materials: For each material, 48 specimens (64 × 10 × 3.3 mm) were made and divided into 6 equal groups (n = 8). In the control group, specimens were untreated. Before testing, specimens were immersed in 200 mL of distilled water and submitted to disinfection for 1 of the following irradiation times: 1, 2, 3, 4, or 5 minutes. The irradiation procedure was performed twice. The flexural strength was determined using a testing machine MTS-810 and measurements of Vickers hardness were made on Micromet 2100. The values were submitted to ANOVA and Tukey's test (P = .05). Results: The K material showed a significant increase (P = .0010) in flexural strength following 5 minutes of disinfection compared to control specimens. The flexural strength mean values of materials T, U, and N were not significantly affected (P > .05) by disinfection. Compared to the control group, the K material showed a significant increase in hardness (P < .001) following disinfection for 3, 4, and 5 minutes. For material U, disinfection for 4 and 5 minutes produced specimens with significantly increased hardness values (P < .001) compared to the control group. For material N, disinfection for 5 minutes resulted in significantly higher hardness values (P < .001) than the control group. Conclusion: Regardless of the irradiation time, the flexural strength and hardness of the materials evaluated were not detrimentally affected by microwave disinfection.en
dc.description.affiliationDepartment of Dental Materials and Prosthodontics São Paulo State University UNESP, São Paulo
dc.description.affiliationFaculdade de Odontologia de Araraquara - UNESP, Rua Humaitá, no. 1680, Araraquara, São Paulo, C.E.P.: 14801-903
dc.description.affiliationUnespDepartment of Dental Materials and Prosthodontics São Paulo State University UNESP, São Paulo
dc.description.affiliationUnespFaculdade de Odontologia de Araraquara - UNESP, Rua Humaitá, no. 1680, Araraquara, São Paulo, C.E.P.: 14801-903
dc.format.extent833-840
dc.identifier.citationQuintessence International, v. 39, n. 10, p. 833-840, 2008.
dc.identifier.issn0033-6572
dc.identifier.scopus2-s2.0-54449094716
dc.identifier.urihttp://hdl.handle.net/11449/231851
dc.language.isoeng
dc.relation.ispartofQuintessence International
dc.sourceScopus
dc.subjectAcrylic resins
dc.subjectCross infection
dc.subjectDisinfection
dc.subjectFlexural strength
dc.subjectHardness
dc.subjectMicrowave