Flexible room-temperature volatile organic compound sensors based on reduced graphene oxide-WO3·0.33H2O nano-needles
dc.contributor.author | Perfecto, Tarcísio M. [UNESP] | |
dc.contributor.author | Zito, Cecilia A. [UNESP] | |
dc.contributor.author | Mazon, Talita | |
dc.contributor.author | Volanti, Diogo P. [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Center for Information Technology Renato Archer (CTI) | |
dc.date.accessioned | 2018-12-11T16:52:24Z | |
dc.date.available | 2018-12-11T16:52:24Z | |
dc.date.issued | 2018-01-01 | |
dc.description.abstract | Flexible sensors have attracted significant attention due to their currently desirable properties and possibility to be applied to any surface and conditions such as wearable electronic devices. Therefore, we prepared volatile organic compound (VOC) sensors based on WO3·0.33H2O nano-needles and their composites with reduced graphene oxide (RGO) on flexible polyethylene terephthalate (PET) substrates. The materials were synthesized via a combination of the ultrasonic spray nozzle (USN) and microwave-assisted hydrothermal (MAH) methods to obtain a single WO3·0.33H2O orthorhombic crystalline phase. The VOC sensing properties of the materials deposited on PET electrodes were studied at room temperature (22 °C) and 55% relative humidity. The materials were exposed to acetone, ethanol, isopropanol, acetic acid, and methanol to determine their selectivity. The materials exhibited a good selectivity for isopropanol. The 5%RGO-WO3·0.33H2O composite presented a superior isopropanol-sensing performance, with a response of 4.96 to 100 ppm, which was ∼1.6 times higher than that of the pure WO3·0.33H2O nano-needles. The materials behaved as p-type semiconductors due to an inversion of the sensitive layer promoted by the adsorption of water molecules on the surface of the material. | en |
dc.description.affiliation | Laboratory of Materials for Sustainability (LabMatSus) Ibilce São Paulo State University (Unesp), R. Cristóvão Colombo, 2265 | |
dc.description.affiliation | Center for Information Technology Renato Archer (CTI), Rod. D. Pedro I, KM 143, 6 | |
dc.description.affiliationUnesp | Laboratory of Materials for Sustainability (LabMatSus) Ibilce São Paulo State University (Unesp), R. Cristóvão Colombo, 2265 | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorship | Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) | |
dc.description.sponsorshipId | FAPESP: 2013/23886-4 | |
dc.description.sponsorshipId | FAPESP: 2016/04371-1 | |
dc.description.sponsorshipId | FAPESP: 2016/25267-8 | |
dc.description.sponsorshipId | FAPESP: 2017/01267-1 | |
dc.description.sponsorshipId | CNPq: 444926/2014-3 | |
dc.format.extent | 2822-2829 | |
dc.identifier | http://dx.doi.org/10.1039/c8tc00324f | |
dc.identifier.citation | Journal of Materials Chemistry C, v. 6, n. 11, p. 2822-2829, 2018. | |
dc.identifier.doi | 10.1039/c8tc00324f | |
dc.identifier.issn | 2050-7526 | |
dc.identifier.issn | 2050-7534 | |
dc.identifier.lattes | 2354739980406725 | |
dc.identifier.orcid | 0000-0001-9315-9392 | |
dc.identifier.scopus | 2-s2.0-85044065035 | |
dc.identifier.uri | http://hdl.handle.net/11449/170786 | |
dc.language.iso | eng | |
dc.relation.ispartof | Journal of Materials Chemistry C | |
dc.relation.ispartofsjr | 1,917 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Scopus | |
dc.title | Flexible room-temperature volatile organic compound sensors based on reduced graphene oxide-WO3·0.33H2O nano-needles | en |
dc.type | Artigo | |
unesp.author.lattes | 2354739980406725[4] | |
unesp.author.orcid | 0000-0001-9315-9392[4] |