Logotipo do repositório
 

Publicação:
Relation between Insertion Torque and Implant Stability Quotient: A Clinical Study

dc.contributor.authorVale Souza, João Paulo Do [UNESP]
dc.contributor.authorMelo Neto, Clóvis Lamartine De Moraes [UNESP]
dc.contributor.authorPiacenza, Lucas Tavares [UNESP]
dc.contributor.authorDa Silva, Emily Vivianne Freitas [UNESP]
dc.contributor.authorMoreno, André Luiz De Melo [UNESP]
dc.contributor.authorPenitente, Paulo Augusto [UNESP]
dc.contributor.authorBrunetto, Juliana Lujan [UNESP]
dc.contributor.authorSantos, Daniela Micheline Dos [UNESP]
dc.contributor.authorGoiato, Marcelo Coelho [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.date.accessioned2022-04-29T08:30:41Z
dc.date.available2022-04-29T08:30:41Z
dc.date.issued2021-01-01
dc.description.abstractObjectives This study aimed to assess the relation between the insertion torque and implant stability quotient (ISQ recorded immediately and 6 months after implant placement). Materials and Methods Twenty-five patients over the age of 18 years were selected for this study. One implant was placed per patient after tooth extraction. The implant site needed 15 mm in height and 8 mm in width. All implants had the same size (11.5 × 3.75 mm) and brand (Hexagonal Morse cone, DSP Biomedical). The insertion torque (Ncm) and resonance frequency analysis (ISQ value) (Osstell Mentor) were used to assess the primary stability (on the day of surgery). After 6 months, ISQ value was used to assess the secondary stability of each implant. Statistical Analysis The insertion torque data were correlated with ISQ measurements by using Pearson's correlation. The significance level was 5%. Results There was a positive correlation between insertion torque and initial ISQ (correlation: 0.457; p = 0.022); however, no correlation was found between insertion torque and final ISQ (p = 0.308). Conclusion The present study demonstrated that there is a positive correlation between the insertion torque and the initial ISQ. Therefore, the higher the insertion torque, the higher the initial ISQ (or vice versa).en
dc.description.affiliationDepartment of Dental Materials and Prosthodontics Araçatuba Dental School São Paulo State University José Bonifácio, 1153, Vila Mendonça, Araçatuba
dc.description.affiliationOral Oncology Center Araçatuba Dental School São Paulo State University Araçatuba
dc.description.affiliationUnespDepartment of Dental Materials and Prosthodontics Araçatuba Dental School São Paulo State University José Bonifácio, 1153, Vila Mendonça, Araçatuba
dc.description.affiliationUnespOral Oncology Center Araçatuba Dental School São Paulo State University Araçatuba
dc.identifierhttp://dx.doi.org/10.1055/s-0041-1725575
dc.identifier.citationEuropean Journal of Dentistry.
dc.identifier.doi10.1055/s-0041-1725575
dc.identifier.issn1305-7464
dc.identifier.issn1305-7456
dc.identifier.scopus2-s2.0-85110053522
dc.identifier.urihttp://hdl.handle.net/11449/229136
dc.language.isoeng
dc.relation.ispartofEuropean Journal of Dentistry
dc.sourceScopus
dc.subjectdental implants
dc.subjectdental prosthesis
dc.subjectresonance frequency analysis
dc.subjecttorque
dc.titleRelation between Insertion Torque and Implant Stability Quotient: A Clinical Studyen
dc.typeArtigopt
dspace.entity.typePublication
relation.isDepartmentOfPublication5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isDepartmentOfPublication.latestForDiscovery5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais odontológicos e Prótese - FOApt

Arquivos