Logotipo do repositório
 

Publicação:
Tela de sombreamento e pintura em telhados de modelos reduzidos de galpões avícolas

dc.contributor.advisorFurlan, Renato Luís [UNESP]
dc.contributor.advisorMilani, Adhemar Pitelli [UNESP]
dc.contributor.authorGomes Filho, João Soares [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-06-11T19:33:33Z
dc.date.available2014-06-11T19:33:33Z
dc.date.issued2010-09-21
dc.description.abstractQuatro experimentos foram conduzidos para avaliar o efeito do sombreamento artificial e da pintura dos telhados na melhoria do conforto térmico de modelos reduzidos simulando galpões avícolas. Em todos os experimentos foram utilizadas coberturas com telha de fibrocimento, novas, sem cimento amianto, com 4,0mm de espessura. O Experimento 1 foi realizado na Universidade Estadual do Maranhão (UEMA), câmpus de São Luís, onde foram testados cinco tipos de coberturas: 1- sem tela, sem pintura (STSP – controle); 2- com tela a 0,05m de altura da telha, sem pintura (CT5SP); 3- com tela a 0,05m de altura da telha, com pintura (CT5CP); 4- com tela a 0,08m de altura da telha, sem pintura (CT8SP) e 5- com tela a 0,08m de altura da telha, com pintura (CT8CP). Foram determinados o Índice de Temperatura de Globo Negro e Umidade (ITGU), a Carga Térmica de Radiação (CTR) e a Entalpia Específica (H). As colheitas das variáveis meteorológicas (temperaturas de globo negro, de bulbo seco, de bulbo úmido e velocidade do vento) foram realizadas durante 12 dias experimentais (04 a 15 de nov. de 2009) às 10:00, 12:00, 14:00 e 16:00 horas. O tipo de cobertura CT5SP foi o que apresentou os melhores valores para ITGUcorr (79,81) e H (78,84 KJ.Kg-1 de ar seco). O melhor resultado para CTRcorr foi apresentado pelo tratamento CT5CP (480,12 W.m-2). O Experimento 2 foi realizado na Universidade Estadual Paulista (UNESP), câmpus de Jaboticabal, onde foram testados os mesmos tipos de coberturas do Experimento 1. As colheitas e registro das variáveis meteorológicas foram realizadas por 40 dias (13 de fev. a 24 de mar. de 2010), nos mesmos horários do Experimento 1. O tipo cobertura que proporcionou menor resultado para o ITGU (83,86) e H (86,41 KJ.Kg-1 de ar seco) foi o CT8CP. A menor CTR (549,52 W.m-2) foi verificada na cobertura CT5CP. O Experimento 3 objetivou verificar o efeito de dois tipos de telas...pt
dc.description.abstractFour experiments were conducted to assess the effect of shading and painting of roofs improving thermal comfort in reduced models of poultry houses. In all the experiments were used with roofing cement tile, new, no asbestos cement, with 4.0 mm thick. The first experiment was conducted at the Universidade Estadual do Maranhão (UEMA), campus of São Luís, where were tested five types of coverage: 1 - no shading, no paint (STSP - control), 2 - with shading 0.05 m in height tile, unpainted (CT5SP) 3 - with shading 0.05 m in height tile with painting (CT5CP) 4 - with shading 0.08 m in height tile, unpainted (CT8SP) and 5 – with shading 0.08 m height of the tile with painting (CT8CP). Were evaluated the index of black globe temperature and humidity (BGTHI), the Heat Load (HL) and the specific enthalpy (H). The readings of meteorological variables (black globe temperature, dry bulb, wet bulb temperatures and wind speed) were measured during 12 experimental days (from nov. 4th to 15th, 2009) at 10:00, 12:00, 14: 00 and 16:00 hours. The type of coverage CT5SP had the lowest values for BGTHI (79,81) and H (78,84 KJ.Kg-1 dry air). The best result for CTRcorr (480,12 W.m-2) was presented by treatment CT5CP. The second experiment was conducted at Universidade Estadual Paulista (UNESP), campus of Jaboticabal, where were tested the same types of coverages of Experiment 1. The collection and recording of meteorological variables were performed for 40 days (from feb. 13th to 24th, 2010), at the same times of Experiment 1. The type coverage that provided smaller results for the BGTHI (83,86) and H (86,41 KJ.Kg-1 dry air) was CT8CP. The lower HL (549,52 W.m-2) was verified with the coverage CT5CP. The third experiment aimed at assessing the effect of two types of shading screens (50 and 80%) on the thermal comfort... (Complete abstract click electronic access below)en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.format.extentxiii, 66 f. : il.
dc.identifier.aleph000639026
dc.identifier.capes33004102002P0
dc.identifier.citationGOMES FILHO, João Soares. Tela de sombreamento e pintura em telhados de modelos reduzidos de galpões avícolas. 2010. xiii, 66 f. Tese (doutorado) - Universidade Estadual Paulista, Faculdade de Ciências Agrárias e Veterinárias, 2010.
dc.identifier.filegomesfilho_js_dr_jabo.pdf
dc.identifier.lattes4512575590159134
dc.identifier.lattes0806409484159642
dc.identifier.orcid0000-0001-9549-0329
dc.identifier.urihttp://hdl.handle.net/11449/104944
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rights.accessRightsAcesso aberto
dc.sourceAleph
dc.subjectEntalpiapt
dc.subjectCarga térmica de radiaçãopt
dc.subjectCobertura de fibrocimentopt
dc.subjectEntalpia específicapt
dc.subjectÍndice de temperatura de globo negro e umidadept
dc.subjectModelos reduzidospt
dc.subjectTela de sombreamentopt
dc.subjectEnthalpyen
dc.subjectHeat loaden
dc.subjectCement roofen
dc.subjectSpecific enthalpyen
dc.subjectBlack globe temperature humidity indexen
dc.subjectReduced modelsen
dc.subjectArtificial shadingen
dc.titleTela de sombreamento e pintura em telhados de modelos reduzidos de galpões avícolaspt
dc.typeTese de doutorado
dspace.entity.typePublication
unesp.advisor.lattes0806409484159642[1]
unesp.advisor.orcid0000-0001-9549-0329[1]
unesp.author.lattes4512575590159134
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Ciências Agrárias e Veterinárias, Jaboticabalpt
unesp.graduateProgramZootecnia - FCAVpt
unesp.knowledgeAreaProdução animalpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
gomesfilho_js_dr_jabo.pdf
Tamanho:
747.6 KB
Formato:
Adobe Portable Document Format