Logotipo do repositório
 

Publicação:
Influência da incorporação de vidro bioativo em diferentes propriedades de sistemas adesivos

dc.contributor.advisorRastelli, Alessandra Nara de Souza [UNESP]
dc.contributor.authorCosta, Joatan Lucas de Sousa Gomes [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2019-05-02T12:00:35Z
dc.date.available2019-05-02T12:00:35Z
dc.date.issued2019-02-28
dc.description.abstractO presente estudo teve como objetivo avaliar o efeito da adição de micropartículas (MPs) de vidro bioativo F-18 em diferentes concentrações em três sistemas adesivos sobre o grau de conversão, a umectabilidade e a resistência adesiva dos mesmos, assim como o padrão de falha. Os sistemas adesivos AdperTM ScotchTM Bond Multi Purpose (A), AdperTM Single Bond (3M ESPE) (S), e Clearfil SE Bond (Kuraray) (C) foram modificados com concentrações de 0 (controle), 1, 2 e 5% de vidro bioativo F-18. Adicionalmente, a distribuição e dispersão das partículas do vidro bioativo foram verificadas por microscopia eletrônica de varredura (MEV). Para o grau de conversão, se obtiveram espectros de absorção dos sistemas adesivos curados e não curados. Para o teste da umectabilidade, os sistemas adesivos modificados ou não foram dispensados sobre as superfícies dentinárias de dentes bovinos, e os ângulos de contato foram mensurados por meio de goniômetro. Para o teste de microcisalhamento, foram confeccionados espécimes em resina composta em substrato bovino, sobre os quais os sistemas adesivos, modificados ou não, foram aplicados, sendo feitas as análises de resistência adesiva após 24 horas. O padrão de falha dos espécimes foi analisado em lupa estereoscópica e por microscopia eletrônica de varredura (MEV). Os resultados foram obtidos e analisados pelo teste de Análise de Variância ANOVA (2 fatores) com pós teste Tukey. Foi observado que não houve diferenças entre os grupos controle e modificados (p>0,05). O sistema adesivo S apresentou melhores resultados em todos os testes avaliados. O padrão de falha predominante foi adesiva, independente do sistema adesivo e da concentração de vidro bioativo. Pôde-se concluir que a adição de micropartículas de vidro bioativo F-18 não prejudicaram as propriedades avaliadas nos diferentes sistemas adesivos, se tornando uma alternativa interessante à associação dos mesmos.pt
dc.description.abstractThis study aimed to evaluate the effect of the incorporation of F-18 bioactive glass microparticles (MPs) in different concentrations in three adhesive systems on the degree of conversion, wettability and adhesive strength, as well as the failure pattern. Adper™ Scotch™ Bond Multi Purpose, Adper™ Single Bond (3M ESPE), and Clearfil SE Bond (Kuraray) adhesive systems were modified with concentrations of 0 (control), 1, 2 and 5% F-18 bioactive glass. In addition, the distribution and dispersion of bioactive glass particles were verified by scanning electron microscopy (SEM). For the degree of conversion, absorption spectra of cured and uncured adhesive systems were obtained. For the wettability test, adhesive systems modified or not were dispensed on the dentin surfaces of bovine teeth, and the contact angles were measured by goniometer. For the microshear test, specimens were made in composite resin on bovine substrate, on which adhesive systems, modified or not, were applied, and the adhesive strength tests were done after 24 hours. The failure pattern of the specimens was analyzed in a stereoscopic magnifying glass and by scanning electron microscopy (SEM). The results were obtained and analyzed by ANOVA Variance Analysis (2 factors) with Tukey test. It was observed that there were no differences between the control and modified groups (p> 0.05). The predominant failure pattern was adhesive. It was concluded that the addition of F-18 bioactive glass microparticles did not influence on the properties evaluated in the different adhesive systems, becoming an interesting alternative.en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.identifier.aleph000915942
dc.identifier.capes33004030010P2
dc.identifier.urihttp://hdl.handle.net/11449/181874
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rights.accessRightsAcesso abertopt
dc.subjectAdesivos dentináriospt
dc.subjectVidropt
dc.subjectPropriedades físicaspt
dc.subjectMateriais biocompatíveispt
dc.subjectDental adhesivesen
dc.subjectGlassen
dc.subjectPhysical propertiesen
dc.subjectBiocompatible materialsen
dc.titleInfluência da incorporação de vidro bioativo em diferentes propriedades de sistemas adesivospt
dc.title.alternativeInfluence of the incorporation of bioactive glass in different properties of adhesive systemsen
dc.typeDissertação de mestradopt
dspace.entity.typePublication
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.advisor.lattes6914969526213393
unesp.advisor.orcid0000-0002-6768-2670
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.embargo24 meses após a data da defesapt
unesp.graduateProgramCiências Odontológicas - FOARpt
unesp.knowledgeAreaDentísticapt
unesp.researchAreaEnsaios laboratoriais e clínicos para análise física,química, mecânica e biológica de biomateriais, equipamentos e substâncias utilizadas em dentística restauradorapt

Arquivos

Pacote Original

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
costa_jlsg_me_arafo_par.pdf
Tamanho:
866.56 KB
Formato:
Adobe Portable Document Format
Descrição:
Carregando...
Imagem de Miniatura
Nome:
costa_jlsg_me_arafo_int.pdf
Tamanho:
2.09 MB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
3 KB
Formato:
Item-specific license agreed upon to submission
Descrição: