Logotipo do repositório
 

Publicação:
Influence of CVD diamond tips and Er:YAG laser irradiation on bonding of different adhesive systems to dentin

dc.contributor.authorda Silva, Melissa Aline [UNESP]
dc.contributor.authorNicolo, Rebeca Di [UNESP]
dc.contributor.authorBarcellos, Daphne Camara [UNESP]
dc.contributor.authorBatista, Graziela Ribeiro [UNESP]
dc.contributor.authorPucci, Cesar Rogerio [UNESP]
dc.contributor.authorTorres, Carlos Rocha Gomes [UNESP]
dc.contributor.authorBorges, Alessandra Bühler [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:27:32Z
dc.date.available2014-05-27T11:27:32Z
dc.date.issued2013-01-01
dc.description.abstractAim: The aim of this study was to compare the microtensile bond strength of three adhesive systems, using different methods of dentin preparation. Materials and methods: A hundred and eight bovine teeth were used. The dentin from buccal face was exposed and prepared with three different methods, divided in 3 groups: Group 1 (DT)- diamond tip on a high-speed handpiece; Group 2 (CVD)-CVD tip on a ultrasonic handpiece; Group 3 (LA)-Er: YAG laser. The teeth were divided into 3 subgroups, according adhesive systems used: Subgroup 1-Adper Single Bond Plus/3M ESPE (SB) total-etch adhesive; Subgroup 2-Adper Scotchbond SE/3M ESPE (AS) selfetching adhesive; Subgroup 3-Clearfil SE Bond/Kuraray (CS) selfetching adhesive. Blocks of composite (Filtek Z250-3M ESPE) 4 mm high were built up and specimens were stored in deionized water for 24 hours at 37°C. Serial mesiodistal and buccolingual cuts were made and stick-like specimens were obtained, with transversal section of 1.0 mm2. The samples were submitted to microtensile test at 1 mm/min and load of 10 kg in a universal testing machine. Data (MPa) were subjected to ANOVA and Tukey's tests (p < 0.05). Results and conclusion: Surface treatment with Diamond or CVD tips associated with Clearfil SE Bond adhesive produced significantly lower bond strength values compared to other groups. Surface treatment with Er: YAG laser associated with Single Bond Plus or Clearfil SE Bond adhesives and surface treatment with CVD tip associated with Adper Scotchbond SE adhesive produced significantly lower bond strength values compared to surface treatment with diamond or CVD tips associated with Single Bond Plus or Adper Scotchbond SE adhesives. Clinical significance: Interactions between laser and the CVD tip technologies and the different adhesive systems can produce a satisfactory bonding strength result, so that these associations may be beneficial and enhance the clinical outcomes.en
dc.description.affiliationDepartment of Restorative Dentistry Clinical Research Academic Group São José dos Campos School of Dentistry, São Paulo State University, UNESP
dc.description.affiliationDepartment of Social Dentistry and Children's Clinic UNESP-São Paulo State University São Jose dos Campos School of Dentistry, São Paulo
dc.description.affiliationDepartment of Restorative Dentistry UNESP-São Paulo State University São Jose dos Campos School of Dentistry, São Paulo
dc.description.affiliationUnespDepartment of Restorative Dentistry Clinical Research Academic Group São José dos Campos School of Dentistry, São Paulo State University, UNESP
dc.description.affiliationUnespDepartment of Social Dentistry and Children's Clinic UNESP-São Paulo State University São Jose dos Campos School of Dentistry, São Paulo
dc.description.affiliationUnespDepartment of Restorative Dentistry UNESP-São Paulo State University São Jose dos Campos School of Dentistry, São Paulo
dc.format.extent14-20
dc.identifierhttp://dx.doi.org/10.5005/jp-journals-10024-1262
dc.identifier.citationJournal of Contemporary Dental Practice, v. 14, n. 1, p. 14-20, 2013.
dc.identifier.doi10.5005/jp-journals-10024-1262
dc.identifier.file2-s2.0-84876835713.pdf
dc.identifier.issn1526-3711
dc.identifier.lattes3135367849609938
dc.identifier.lattes6960470053037905
dc.identifier.lattes1754020652874850
dc.identifier.orcid0000-0003-4830-0400
dc.identifier.scopus2-s2.0-84876835713
dc.identifier.urihttp://hdl.handle.net/11449/74304
dc.language.isoeng
dc.relation.ispartofJournal of Contemporary Dental Practice
dc.relation.ispartofsjr0,263
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectAdhesive system
dc.subjectDentin bond strength
dc.subjectSmear layer
dc.subjectbisphenol A bis(2 hydroxypropyl) ether dimethacrylate
dc.subjectClearfil SE Bond
dc.subjectdentin bonding agent
dc.subjectdiamond
dc.subjectfiltek Z350
dc.subjectresin
dc.subjectresin cement
dc.subjectSingle Bond Plus
dc.subjectwater
dc.subjectanimal
dc.subjectcattle
dc.subjectchemistry
dc.subjectcomparative study
dc.subjectdental bonding
dc.subjectdental device
dc.subjectdental procedure
dc.subjectdental surgery
dc.subjectdentin
dc.subjectequipment
dc.subjectmechanical stress
dc.subjectrandomization
dc.subjectscanning electron microscopy
dc.subjectscotchbond
dc.subjectsolid state laser
dc.subjectsurface property
dc.subjecttemperature
dc.subjecttensile strength
dc.subjecttime
dc.subjectultrasound
dc.subjectultrastructure
dc.subjectAnimals
dc.subjectBisphenol A-Glycidyl Methacrylate
dc.subjectCattle
dc.subjectComposite Resins
dc.subjectDental Bonding
dc.subjectDental Cavity Preparation
dc.subjectDental High-Speed Equipment
dc.subjectDental Stress Analysis
dc.subjectDentin
dc.subjectDentin-Bonding Agents
dc.subjectDiamond
dc.subjectLasers, Solid-State
dc.subjectMicroscopy, Electron, Scanning
dc.subjectRandom Allocation
dc.subjectResin Cements
dc.subjectSmear Layer
dc.subjectStress, Mechanical
dc.subjectSurface Properties
dc.subjectTemperature
dc.subjectTensile Strength
dc.subjectTime Factors
dc.subjectUltrasonics
dc.subjectWater
dc.titleInfluence of CVD diamond tips and Er:YAG laser irradiation on bonding of different adhesive systems to dentinen
dc.typeArtigo
dcterms.licensehttp://www.thejcdp.com/pdfs/copyright_transfer_form.pdf
dspace.entity.typePublication
unesp.author.lattes3135367849609938[6]
unesp.author.lattes6960470053037905[7]
unesp.author.lattes1754020652874850[5]
unesp.author.orcid0000-0001-7686-089X[7]
unesp.author.orcid0000-0002-9485-5514[6]
unesp.author.orcid0000-0003-4830-0400[5]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.departmentOdontologia Restauradora - ICTpt
unesp.departmentOdontologia Social e Clínica Infantil - ICTpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-84876835713.pdf
Tamanho:
237.2 KB
Formato:
Adobe Portable Document Format