Logo do repositório
 

Influence of microwave sterilization on the cutting capacity of carbide burs

dc.contributor.authorGrassi Fais, Laiza Maria [UNESP]
dc.contributor.authorPereira Pinelli, Ligia Antunes [UNESP]
dc.contributor.authorAdabo, Gelson Luis [UNESP]
dc.contributor.authorBarbosa Tavares da Silva, Regina Helena [UNESP]
dc.contributor.authorMarcelo, Caroline Canhizares [UNESP]
dc.contributor.authorGuaglianoni, Dalton Geraldo [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T13:46:27Z
dc.date.available2014-05-20T13:46:27Z
dc.date.issued2009-11-01
dc.description.abstractObjective: This study compared the cutting capacity of carbide burs sterilized with microwaves and traditional sterilization methods. Material and Methods: Sixty burs were divided into 5 groups according to the sterilization methods: dry heat (G1), autoclave (G2), microwave irradiation (G3), glutaraldehyde (G4) or control - no sterilization (G5). The burs were used to cut glass plates in a cutting machine set for twelve 2.5-min periods and, after each period, they were sterilized (except G5) following the protocol established for each group. The cutting capacity of the burs was determined by a weight-loss method. Data were analyzed statistically by Kruskal-Wallis and Dunn's test. Results: The means of the cutting amount performed by each group after the 12 periods were G1 = 0.2167 +/- 0.0627 g; G2 = 0.2077 +/- 0.0231 g; G3 = 0.1980 +/- 0.0326 g; G4 = 0.1203 +/- 0.0459 g; G5 = 0.2642 +/- 0.0359 g. There were statistically significant differences among the groups (p<0.05); only dry heat sterilization was similar to the control. Conclusion: Sterilization by dry heat was the method that least affected the cutting capacity of the carbide burs and microwave sterilization was not better than traditional sterilization methods.en
dc.description.affiliationSão Paulo State Univ, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, Araraquara, SP, Brazil
dc.description.affiliationSão Paulo State Univ, Sch Sci & Letters, Dept Math & Stat, Araraquara, SP, Brazil
dc.description.affiliationUnespSão Paulo State Univ, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, Araraquara, SP, Brazil
dc.description.affiliationUnespSão Paulo State Univ, Sch Sci & Letters, Dept Math & Stat, Araraquara, SP, Brazil
dc.description.sponsorshipPROAP
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.format.extent584-589
dc.identifierhttp://dx.doi.org/10.1590/S1678-77572009000600009
dc.identifier.citationJournal of Applied Oral Science. Bauru-sp: Univ São Paulo Fac Odontologia Bauru, v. 17, n. 6, p. 584-589, 2009.
dc.identifier.fileS1678-77572009000600009.pdf
dc.identifier.issn1678-7757
dc.identifier.lattes0455968557454133
dc.identifier.lattes2851339311179809
dc.identifier.scieloS1678-77572009000600009
dc.identifier.urihttp://hdl.handle.net/11449/16445
dc.identifier.wosWOS:000272950100009
dc.language.isoeng
dc.publisherUniversidade de São Paulo (USP), Faculdade de Odontologia de Bauru
dc.relation.ispartofJournal of Applied Oral Science
dc.relation.ispartofjcr1.709
dc.relation.ispartofsjr0,645
dc.rights.accessRightsAcesso abertopt
dc.sourceWeb of Science
dc.subjectSterilizationen
dc.subjectDental instrumentsen
dc.subjectInfection controlen
dc.subjectMicrowavesen
dc.titleInfluence of microwave sterilization on the cutting capacity of carbide bursen
dc.typeArtigopt
dcterms.licensehttp://www.scielo.br/revistas/jaos/paboutj.htm
dcterms.rightsHolderUniv São Paulo Fac Odontologia Bauru
dspace.entity.typePublication
relation.isDepartmentOfPublication3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isDepartmentOfPublication.latestForDiscovery3936e2e2-946a-42ab-8b9d-9521513200fc
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.lattes0455968557454133
unesp.author.lattes2851339311179809
unesp.author.orcid0000-0002-0734-7926[3]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentMateriais Odontológicos e Prótese - FOARpt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S1678-77572009000600009.pdf
Tamanho:
280.38 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: