Logotipo do repositório
 

Publicação:
Análise da desadaptação marginal vertical e horizontal de infraestruturas de próteses fixas implantossuportadas confeccionadas através de diferentes técnicas.

dc.contributor.advisorPellizzer, Eduardo Piza [UNESP]
dc.contributor.authorGomes, Jéssica Marcela de Luna [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-02-14T16:56:42Zpt
dc.date.available2018-02-14T16:56:42Zpt
dc.date.issued2018-02-05
dc.description.abstractO objetivo deste trabalho foi avaliar a desadaptação marginal vertical, horizontal e interna de infraestruturas e próteses fixas implantossuportadas confeccionadas através de diferentes técnicas. Além disso, realizar uma revisão sistemática e meta-análise avaliando o efeito da soldagem de infraestruturas de próteses fixas implantossuportadas em uma melhor adaptação quando comparada as infraestruturas confeccionadas em monobloco. Um total de 30 infraestruturas foram confeccionadas e divididas em 3 grupos: G1) Técnica convencional da cera perdida (n=10); G2) CAD/CAM (n=10); G3: CAD/CAM + Técnica da cera perdida (n=10). Uma matriz foi utilizada para simular uma prótese fixa implantossuportada de três elementos com um pôntico central. A infraestrutura do grupo G1 foi confeccionada em Ni-Cr, do grupo G2 em zircônia e G3 fresada em cera e fundida em Ni-Cr. Em todos os grupos a desadaptação marginal vertical e horizontal (subcontorno e sobrecontorno) foi avaliada através de um microscópio óptico tridimensional (Quick Scope, Mitutoyo). A revisão sistemática seguiu o critério PRISMA e está cadastrada na plataforma PROSPERO (CRD81865) e a busca foi realizada nas bases de dados Pubmed/MEDLINE, Embase and The Cochrane Library com artigos publicados até novembro de 2017. A questão PICO foi: “A técnica do ponto de solda contribui para uma melhor adaptação quando comparada a confecção em monobloco de infraestruturas e próteses fixas implantossuportadas?”. O estudo in vitro demonstrou maior valor de desadaptação marginal vertical para o grupo G3 (83.5µm), seguido dos grupos G1 (55 µm) e G2 (42 µm) (p<0,001). Quanto à desadaptação marginal horizontal, o maior valor de desadaptação foi do grupo G2 (118 µm), seguido de G3 (102 µm), ambos apresentando sobre contorno. O grupo G1 (- 85 µm) apresentou valores de sub contorno (p<0,001). Na revisão sistemática, 12 estudos foram selecionados para análise qualitativa e 7 estudos para análise quantitativa. Um total de189 espécimes foram avaliados, em diferentes ligas metálicas (cp-Ti; Ni-Cr; Cr-Co e ligas nobres) e técnicas de soldagem: laser welding, solda convencional, TIG e brazing. As desadaptações marginais verticais foram mensuradas através de microscópio óptico, estereomicroscópio e MEV. Uma análise qualitativa dos estudos foi realizada demonstrando um efeito positivo da soldagem na adaptação das infraestruturas quando comparadas aquelas confeccionadas em monobloco. A meta-análise confirmou o efeito positivo da soldagem na adaptação (P<0.00001; MD: -36.14; IC 95%: -48.69 to -23.59). Dentro das limitações pertinentes a um estudo in vitro pode-se concluir a confecção de infraestruturas através dos sistemas CAD/CAM apresentou os menores valores de DMV. A associação dos sistemas CAD/CAM e a técnica convencional da cera perdida, apresentou maior DMV. A DMH foi mais favorável quando confeccionadas infraestruturas pela técnica da cera perdida, apresentando sub-contorno. A revisão sistemática demonstrou que a técnica do ponto de solda é eficaz para obtenção de menores valores de desadaptação marginal, sendo a técnica do laser (laser welding) a mais eficaz.pt
dc.description.abstractThe aim of this study was to evaluate the marginal vertical, horizontal and internal misfit of implant-supported prostheses made through different techniques. In addition, to perform a systematic review and meta-analysis evaluating the effect of the welding technique on fixed prosthesis implants supported in make a better adaptation when compared the infrastructures made in one piece cast. A total of 30 infrastructures were made and divided into 3 groups: G1) Conventional- lost wax technique (n = 10); G2) CAD/CAM (n = 10); G3: CAD/CAM + lost wax technique (n = 10). A reference model was used to to simulate a 3-unit implant-supported fixed prostheses with a central pontic. In the G1 group the frameworks were made of Ni-Cr alloy, G2 group in zirconia and G3 milled in wax and fused in Ni-Cr alloy. In all groups, vertical and horizontal marginal misfit (under-contour and over-contour) was evaluated using a 3D optical microscope (Quick Scope, Mitutoyo, Japan). The systematic review and meta-analysis followed the PRISMA criteria and is registered on the PROSPERO (CRD81865). The search was performed in the Pubmed/MEDLINE, Embase and The Cochrane Library databases with selection of articles published until November 2017. The PICO question was: "The welding technique contributes to a better adaptation when compared to the one-piece cast frameworks of implant-supported prostheses?" The in vitro study showed a higher value of vertical marginal misfit for the G3 group (83.5μm), followed by G1 (55μm) and G2 (42μm) (p <0.001). As for horizontal marginal misfit, the highest value of misfit was G2 (118 μm), followed by G3 (102 μm), both presenting over-contour. The G1 group (-85 μm) had under-contour values (p <0.001). In the systematic review, 12 studies were selected for qualitative analysis and 7 studies for quantitative analysis. A total of 189 specimens were evaluated in different metal alloys (cp-Ti, Ni-Cr, Cr-Co and noble alloys) and welding techniques: laser welding, conventional welding, TIG and brazing. Vertical marginal misfits were measured by optical microscope, stereomicroscope and/or SEM. A qualitative analysis of the studies was performed demonstrating a positive effect of welding technique on the adaptation of the frameworks when compared to those made in one piece cast. The meta-analysis confirmed the positive effect of welding on marginal adaptation (P <0.00001; MD: -36.14; 95% CI: -48.69 to -23.59). Within the limitations of an in vitro study it can be concluded that the construction of infrastructures through CAD/CAM systems presented the lowest values of DMV. The association of the CAD/CAM systems and the conventional lost wax technique presented higher DMV. The DMH was more favorable when frameworks were made by the lost wax technique, presenting under-contour. The systematic review showed that the welding technique is effective to obtain lower values of marginal misfit and the Laser Welding technique is the most effective.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipId11/06311-5
dc.identifier.aleph000897013
dc.identifier.capes33004021011P0
dc.identifier.urihttp://hdl.handle.net/11449/152727
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rights.accessRightsAcesso abertopt
dc.subjectPrótese dentária sobre implantespt
dc.subjectAdaptação marginal dentáriapt
dc.subjectProjeto auxiliado por computadorpt
dc.subjectSoldagem em odontologiapt
dc.subjectDental prosthesis Implant-supporteden
dc.subjectDental marginal adaptationen
dc.subjectComputer-aided designen
dc.subjectDental solderingen
dc.titleAnálise da desadaptação marginal vertical e horizontal de infraestruturas de próteses fixas implantossuportadas confeccionadas através de diferentes técnicas.pt
dc.title.alternativeAnalysis of vertical and horizontal marginal misfit of implant-supported fixed prosthesis made through different techniques.en
dc.typeDissertação de mestradopt
dspace.entity.typePublication
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.embargo18 meses após a data da defesapt
unesp.graduateProgramOdontologia - FOApt
unesp.knowledgeAreaPrótese dentáriapt
unesp.researchAreaAvaliação da precisão em reabilitações orais confeccionadas pela tecnologia CAD/CAM.pt

Arquivos

Pacote Original

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
gomes_jml_me_araca_par.pdf
Tamanho:
850.02 KB
Formato:
Adobe Portable Document Format
Descrição:
Carregando...
Imagem de Miniatura
Nome:
gomes_jml_me_araca_int.pdf
Tamanho:
1.41 MB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
3.07 KB
Formato:
Item-specific license agreed upon to submission
Descrição: