Publicação: Effect of pre-heating resin composite and light-curing units on monomer conversion
Carregando...
Data
Orientador
Coorientador
Pós-graduação
Curso de graduação
Título da Revista
ISSN da Revista
Título de Volume
Editor
Tipo
Artigo
Direito de acesso
Acesso restrito
Resumo
The purpose of this study was to evaluate the effect of pre-heating resin composite photo-cured with light-curing units (LCU) by FT-IR. Twenty specimens were made in a metallic mold (4 mm diameter × 2 mm thick) from composite resin-Tetric Ceram® (Ivoclar/Vivadent) at room temperature (25°C) and pre-heated to 37, 54, and 60°C. The specimens were cured with halogen curing light (QTH) and light emitted by diodes (LED) during 40 s. Then, the specimens were pulverized, pressed with KBr and analyzed with FT-IR. The data were submitted to statistical analysis of variance and Kruskal-Wallis test. Study data showed no statistically significant difference to the degree of conversion for the different light curing units (QTH and LED) (p > 0.05). With the increase of temperature there was significant increase in the degree of conversion (p < 0.05). In this study were not found evidence that the light curing unit and temperature influenced the degree of conversion. © 2010 Pleiades Publishing, Ltd.
Descrição
Palavras-chave
Composite resins, Degree of conversion, Halogen curing, Kruskal, Light-curing units, Metallic mold, Monomer conversions, Resin composites, Room temperature, Statistical analysis, Statistically significant difference, Dental composites, Heating, Light emitting diodes, Regression analysis, Resins, Curing
Idioma
Inglês
Como citar
Laser Physics, v. 20, n. 1, p. 285-290, 2010.