dc.description.abstractThe purpose of this study was to evaluate the effect of pre-heating resin composite photo-cured with light-curing units (LCU) by FT-IR. Twenty specimens were made in a metallic mold (4 mm diameter × 2 mm thick) from composite resin-Tetric Ceram® (Ivoclar/Vivadent) at room temperature (25°C) and pre-heated to 37, 54, and 60°C. The specimens were cured with halogen curing light (QTH) and light emitted by diodes (LED) during 40 s. Then, the specimens were pulverized, pressed with KBr and analyzed with FT-IR. The data were submitted to statistical analysis of variance and Kruskal-Wallis test. Study data showed no statistically significant difference to the degree of conversion for the different light curing units (QTH and LED) (p > 0.05). With the increase of temperature there was significant increase in the degree of conversion (p < 0.05). In this study were not found evidence that the light curing unit and temperature influenced the degree of conversion. © 2010 Pleiades Publishing, Ltd.en
dc.description.affiliationAraraquara School of Dentistry Department of Restorative Dentistry University of São Paulo State, Humaitá St., 1680, Araraquara, SP 14801-903
dc.description.affiliationUniversity of Sagrado Coração, 10-50 Irmã Arminda St., Bauru 17011-160
dc.description.affiliationSão Carlos Physics Institute University of São Paulo, Trabalhador São Carlense Avenue 400, São Carlos, SP 13566-970
dc.format.extent285-290
dc.identifierhttp://dx.doi.org/10.1134/S1054660X10010172
dc.identifier.citationLaser Physics, v. 20, n. 1, p. 285-290, 2010.
dc.identifier.doi10.1134/S1054660X10010172
dc.identifier.issn1054-660X
dc.identifier.issn1555-6611
dc.identifier.lattes6914969526213393
dc.identifier.scopus2-s2.0-76849098494
dc.identifier.urihttp://hdl.handle.net/11449/71508
dc.language.isoeng
dc.relation.ispartofLaser Physics
dc.relation.ispartofjcr1.158
dc.relation.ispartofsjr0,345
dc.rights.accessRightsAcesso restritopt
dc.sourceScopus
dc.subjectComposite resins
dc.subjectDegree of conversion
dc.subjectHalogen curing
dc.subjectKruskal
dc.subjectLight-curing units
dc.subjectMetallic mold
dc.subjectMonomer conversions
dc.subjectResin composites
dc.subjectRoom temperature
dc.subjectStatistical analysis
dc.subjectStatistically significant difference
dc.subjectDental composites
dc.subjectHeating
dc.subjectLight emitting diodes
dc.subjectRegression analysis
dc.subjectResins
dc.subjectCuring
dc.titleEffect of pre-heating resin composite and light-curing units on monomer conversionen
dc.typeArtigopt
dcterms.licensehttp://www.springer.com/open+access/authors+rights
dspace.entity.typePublication
relation.isDepartmentOfPublication901124bf-5736-4432-b057-7c29dec84b50
relation.isDepartmentOfPublication.latestForDiscovery901124bf-5736-4432-b057-7c29dec84b50
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.author.lattes6914969526213393[5]
unesp.author.orcid0000-0002-6768-2670[5]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentOdontologia Restauradora - FOARpt

Arquivos