Logotipo do repositório
 

Publicação:
Influence of microgap location and configuration on radiographic bone loss around submerged implants: An experimental study in dogs

Carregando...
Imagem de Miniatura

Orientador

Coorientador

Pós-graduação

Curso de graduação

Título da Revista

ISSN da Revista

Título de Volume

Editor

Tipo

Artigo

Direito de acesso

Resumo

Purpose: The vertical location of the implant-abutment connection influences the subsequent reaction of the peri-implant bone. It is not known, however, whether any additional influence is exerted by different microgap configurations. Therefore, the radiographic bone reactions of two different implant systems were monitored for 6 months. Materials and Methods: In eight mongrel dogs, two implants with an internal Morse-taper connection (INT group) were placed on one side of the mandible; the contralateral side received two implants with an external-hex connection (EXT group). On each side, one implant was aligned at the bone level (equicrestal) and the second implant was placed 1.5 mm subcrestal. Healing abutments were placed 3 months after submerged healing, and the implants were maintained for another 3 months without prosthetic loading. At implant placement and after 1, 2, 3, 4, 5, and 6 months, standardized radiographs were obtained, and peri-implant bone levels were measured with regard to microgap location and evaluated statistically. Results: All implants osseointegrated clinically and radiographically. The overall mean bone loss was 0.68 ± 0.59 mm in the equicrestal INT group, 1.32 ± 0.49 mm in the equicrestal EXT group, 0.76 ± 0.49 mm in the subcrestal INT group, and 1.88 ± 0.81 mm in the subcrestal EXT group. The differences between the INT and EXT groups were statistically significant (paired t tests). The first significant differences between the internal and external groups were seen at month 1 in the subcrestal groups and at 3 months in the equicrestal groups. Bone loss was most pronounced in the subcrestal EXT group. Conclusions: Within the limits of this study, different microgap configurations can cause different amounts of bone loss, even before prosthetic loading. Subcrestal placement of a butt-joint microgap design may lead to more pronounced radiographic bone loss. © 2011 by Quintessence Publishing Co Inc.

Descrição

Palavras-chave

Bone morphology, Crestal implant placement, Implant-abutment microgap, Radiographic study, Subcrestal placement

Idioma

Inglês

Como citar

International Journal of Oral and Maxillofacial Implants, v. 26, n. 5, p. 941-946, 2011.

Itens relacionados

Financiadores

Unidades

Unidade
Faculdade de Odontologia
FOA
Campus: Araçatuba

Departamentos

Cursos de graduação

Programas de pós-graduação