Logotipo do repositório
 

Publicação:
Comparison of synthetic hydroxyapatite and porous polyethylene implants in eviscerated rabbit eyes

dc.contributor.authorSchellini, Silvana Artioli [UNESP]
dc.contributor.authorMarques, MEA
dc.contributor.authorPadovani, Carlos Roberto [UNESP]
dc.contributor.authorTaga, E. M.
dc.contributor.authorRossa, R.
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.date.accessioned2014-05-20T13:36:57Z
dc.date.available2014-05-20T13:36:57Z
dc.date.issued2003-03-01
dc.description.abstractPurpose: Synthetic hydroxyapatite and porous polyethylene (Polipore) spheres were placed in rabbits' eviscerated cavities to evaluate tissue reaction and volume maintenance.Methods. Fifty-six Norfolk albino rabbits underwent unilateral evisceration and implantation of synthetic hydroxyapatite (H group, 28 animals) or porous polyethylene spheres (P group, 28 animals). Postoperative reactions, animal behavior, and socket conditions were monitored. Light microscopy and morphometric evaluation with statistical analysis of the exenterated orbits were performed at 7, 15, 30, 60, 90, 120, and 180 days. Scanning electron microscopy was appraised 7, 60, and 180 days after surgery.Results: Two animals from the H group and 1 from the P group had extrusion 7 days after surgery. Throughout the experimental period, the synthetic hydroxyapatite caused more inflammation than the porous polyethylene material. Ingrowth in the sphere occurred 7 to 15 days after the surgery in both groups, and the tissue reaction became denser at approximate to60 to 90 days, when bony metaplasia began in the H group. Volume maintenance was better in the P group and with a smaller pseudocapsule surrounding the implanted sphere than in the H group.Conclusions: Clinical findings demonstrated mild inflammation inside the sphere and in the pseudocapsule surrounding it and better cavity volume maintenance in the P group animals. The authors consider porous polyethylene a more suitable material than synthetic hydroxyapatite for use in anophthalmic cavity reconstruction.en
dc.description.affiliationUniv Estadual Paulista Julio Mesquita Filho, Fac Med, Dept Opftalmol, BR-18618000 Botucatu, SP, Brazil
dc.description.affiliationUniv Estadual Paulista Julio Mesquita Filho, Dept Pathol, BR-18618000 Botucatu, SP, Brazil
dc.description.affiliationUniv Estadual Paulista Julio Mesquita Filho, Dept Biostat, BR-18618000 Botucatu, SP, Brazil
dc.description.affiliationUniv São Paulo, Dept Biochem, São Paulo, SP, Brazil
dc.description.affiliationUniv São Paulo, Dept Maxillofacial Surg, São Paulo, SP, Brazil
dc.description.affiliationUnespUniv Estadual Paulista Julio Mesquita Filho, Fac Med, Dept Opftalmol, BR-18618000 Botucatu, SP, Brazil
dc.description.affiliationUnespUniv Estadual Paulista Julio Mesquita Filho, Dept Pathol, BR-18618000 Botucatu, SP, Brazil
dc.description.affiliationUnespUniv Estadual Paulista Julio Mesquita Filho, Dept Biostat, BR-18618000 Botucatu, SP, Brazil
dc.format.extent136-139
dc.identifierhttp://dx.doi.org/10.1097/01.IOP.0000056028.98833.FF
dc.identifier.citationOphthalmic Plastic and Reconstructive Surgery. Philadelphia: Lippincott Williams & Wilkins, v. 19, n. 2, p. 136-139, 2003.
dc.identifier.doi10.1097/01.IOP.0000056028.98833.FF
dc.identifier.issn0740-9303
dc.identifier.lattes9420249100835492
dc.identifier.lattes8727897080522289
dc.identifier.urihttp://hdl.handle.net/11449/12737
dc.identifier.wosWOS:000181824200009
dc.language.isoeng
dc.publisherLippincott Williams & Wilkins
dc.relation.ispartofOphthalmic Plastic and Reconstructive Surgery
dc.relation.ispartofjcr1.283
dc.relation.ispartofsjr0,615
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.titleComparison of synthetic hydroxyapatite and porous polyethylene implants in eviscerated rabbit eyesen
dc.typeArtigo
dcterms.licensehttp://journals.lww.com/_layouts/oaks.journals/nih.aspx
dcterms.rightsHolderLippincott Williams & Wilkins
dspace.entity.typePublication
unesp.author.lattes9420249100835492
unesp.author.lattes8727897080522289[3]
unesp.author.orcid0000-0002-7719-9682[3]
unesp.author.orcid0000-0002-6938-1230[1]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Biociências, Botucatupt
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Medicina, Botucatupt
unesp.departmentPatologia - FMBpt
unesp.departmentBioestatística - IBBpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: