Publicação: Analysis of biological tissues in infant chest for the development of an equivalent radiographic phantom
dc.contributor.author | Miranda, Diana Rodrigues de Pina [UNESP] | |
dc.contributor.author | Souza, Rafael T. F. [UNESP] | |
dc.contributor.author | Duarte, Sergio B. | |
dc.contributor.author | Alvarez, Matheus [UNESP] | |
dc.contributor.author | Miranda, Jose R. A. [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | MCT | |
dc.date.accessioned | 2014-05-20T13:34:25Z | |
dc.date.available | 2014-05-20T13:34:25Z | |
dc.date.issued | 2012-03-01 | |
dc.description.abstract | Purpose: The main purpose of the present study was to determine the amounts of different tissues in the chest of the newborn patient (age <= 1 year), with the aim of developing a homogeneous phantom chest equivalent. This type of phantom is indispensable in the development of optimization procedures for radiographic techniques, including dosimetric control, which is a crucial aspect of pediatric radiology. The authors present a systematic set of procedures, including a computational algorithm, to estimate the amounts of tissues and thicknesses of the corresponding simulator material plates used to construct the phantom.Methods: The Gaussian fit of computed tomographic (CT) analysis was applied to classify and quantify different biological tissues. The methodology is summarized with a computational algorithm, which was used to quantify tissues through automated CT analysis. The thicknesses of the equivalent homogeneous simulator material plates were determined to construct the phantom.Results: A total of 180 retrospective CT examinations with anterior-posterior diameter values ranging 8.5-13.0 cm were examined. The amounts of different tissues were evaluated. The results provided elements to construct a phantom to simulate the infant chest in the posterior-anterior or anterior-posterior (PA/AP) view.Conclusions: To our knowledge, this report represents the first demonstration of an infant chest phantom dedicated to the radiology of children younger than one year. This phantom is a key element in the development of clinical charts for optimizing radiographic technique in pediatric patients. Optimization procedures for nonstandard patients were reported previously [Pina , Phys. Med. Biol. 49, N215-N226 (2004) and Pina , Appl. Radiat. Isot. 67, 61-69 (2009)]. The constructed phantom represents a starting point to obtain radiologic protocols for the infant patient. (C) 2012 American Association of Physicists in Medicine. [DOI: 10.1118/1.3685588] | en |
dc.description.affiliation | Univ Estadual Paulista UNESP, Fac Med Botucatu, Dept Doencas Tropicais & Diagnost Imagem, BR-18618000 São Paulo, Brazil | |
dc.description.affiliation | Univ Estadual Paulista UNESP, Dept Fis & Biofis, Inst Biociencias Botucatu, BR-18618000 São Paulo, Brazil | |
dc.description.affiliation | MCT, CBPF, BR-22290180 Rio de Janeiro, Brazil | |
dc.description.affiliationUnesp | Univ Estadual Paulista UNESP, Fac Med Botucatu, Dept Doencas Tropicais & Diagnost Imagem, BR-18618000 São Paulo, Brazil | |
dc.description.affiliationUnesp | Univ Estadual Paulista UNESP, Dept Fis & Biofis, Inst Biociencias Botucatu, BR-18618000 São Paulo, Brazil | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorship | Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) | |
dc.format.extent | 1357-1360 | |
dc.identifier | http://dx.doi.org/10.1118/1.3685588 | |
dc.identifier.citation | Medical Physics. Melville: Amer Assoc Physicists Medicine Amer Inst Physics, v. 39, n. 3, p. 1357-1360, 2012. | |
dc.identifier.doi | 10.1118/1.3685588 | |
dc.identifier.issn | 0094-2405 | |
dc.identifier.uri | http://hdl.handle.net/11449/11796 | |
dc.identifier.wos | WOS:000301503400023 | |
dc.language.iso | eng | |
dc.publisher | Amer Assoc Physicists Medicine Amer Inst Physics | |
dc.relation.ispartof | Medical Physics | |
dc.relation.ispartofjcr | 2.884 | |
dc.relation.ispartofsjr | 1,289 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | phantom | en |
dc.subject | biological tissues | en |
dc.subject | simulator materials | en |
dc.subject | quantification | en |
dc.subject | x-ray imaging | en |
dc.title | Analysis of biological tissues in infant chest for the development of an equivalent radiographic phantom | en |
dc.type | Artigo | |
dcterms.license | http://www.medphys.org/documents/copyright.pdf | |
dcterms.rightsHolder | Amer Assoc Physicists Medicine Amer Inst Physics | |
dspace.entity.type | Publication | |
unesp.author.orcid | 0000-0002-8306-8056[5] | |
unesp.campus | Universidade Estadual Paulista (Unesp), Instituto de Biociências, Botucatu | pt |
unesp.campus | Universidade Estadual Paulista (Unesp), Faculdade de Medicina, Botucatu | pt |
unesp.department | Doenças Tropicais e Diagnósticos por Imagem - FMB | pt |
unesp.department | Física e Biofísica - IBB | pt |
Arquivos
Licença do Pacote
1 - 2 de 2
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: