Publicação:
Dose evaluation in medical staff during interventional radiology procedures

dc.contributor.authorBacchim Neto, Fernando Antonio [UNESP]
dc.contributor.authorAlves, A. F.F. [UNESP]
dc.contributor.authorAlvarez, M. [UNESP]
dc.contributor.authorRosa, M. [UNESP]
dc.contributor.authorMacedo De Freitas, C. C. [UNESP]
dc.contributor.authorMoura, R. [UNESP]
dc.contributor.authorPina, D. R. [UNESP]
dc.contributor.authorMiranda, J. [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-12-11T16:57:16Z
dc.date.available2018-12-11T16:57:16Z
dc.date.issued2015-01-01
dc.description.abstractInterventional Radiology is the radiology modality that provides the highest dose values to medical staff. Recent researches show that personal dosimeters may underestimate dose values in interventional physicians, especially in extremities and eye lens. The aim of this work was to study radiation exposure levels of medical staff in different hemodynamics interventional radiology procedures. Dosimeters were positioned in different body regions of the interventional physician. Dose values were compared with annual dose limits for workers thus finding the maximum number of annual procedures that each physician could perform. As each body region of the interventionist is subject to different levels of exposure, dose distribution in each region provides a better approach to what actions are necessary to ensure the radiological protection of medical staff.en
dc.description.affiliationDept. of Physics and Biophysics/Biosciences Institute of Botucatu, Univ. Estadual Paulista (UNESP)
dc.description.affiliationDept. of Neurology and Psychiatry/Botucatu Medical School, Univ. Estadual Paulista (UNESP)
dc.description.affiliationDept. of Surgery and Orthopedics /Botucatu Medical School, Univ. Estadual Paulista (UNESP)
dc.description.affiliationDept. of Tropical Diseases and Diagnosis Imaging/Botucatu Medical School, Univ. Estadual Paulista (UNESP)
dc.description.affiliationUnespDept. of Physics and Biophysics/Biosciences Institute of Botucatu, Univ. Estadual Paulista (UNESP)
dc.description.affiliationUnespDept. of Neurology and Psychiatry/Botucatu Medical School, Univ. Estadual Paulista (UNESP)
dc.description.affiliationUnespDept. of Surgery and Orthopedics /Botucatu Medical School, Univ. Estadual Paulista (UNESP)
dc.description.affiliationUnespDept. of Tropical Diseases and Diagnosis Imaging/Botucatu Medical School, Univ. Estadual Paulista (UNESP)
dc.format.extent927-930
dc.identifierhttp://dx.doi.org/10.1007/978-3-319-13117-7_235
dc.identifier.citationIFMBE Proceedings, v. 49, p. 927-930.
dc.identifier.doi10.1007/978-3-319-13117-7_235
dc.identifier.file2-s2.0-84925238992.pdf
dc.identifier.issn1680-0737
dc.identifier.scopus2-s2.0-84925238992
dc.identifier.urihttp://hdl.handle.net/11449/171814
dc.language.isoeng
dc.relation.ispartofIFMBE Proceedings
dc.relation.ispartofsjr0,143
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectDosimetry
dc.subjectInterventional radiology
dc.subjectRadiation protection
dc.titleDose evaluation in medical staff during interventional radiology proceduresen
dc.typeTrabalho apresentado em evento
dspace.entity.typePublication
unesp.author.lattes3177448334105343[5]
unesp.author.orcid0000-0001-5210-4336[5]
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Medicina, Botucatupt
unesp.campusUniversidade Estadual Paulista (Unesp), Instituto de Biociências, Botucatupt
unesp.departmentCirurgia e Ortopedia - FMBpt
unesp.departmentDoenças Tropicais e Diagnósticos por Imagem - FMBpt
unesp.departmentNeurologia, Psicologia e Psiquiatria - FMBpt
unesp.departmentFísica e Biofísica - IBBpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-84925238992.pdf
Tamanho:
156.25 KB
Formato:
Adobe Portable Document Format
Descrição: