Publicação: Can the modeling for simplification of a dental implant surface affect the accuracy of 3D finite element analysis?
dc.contributor.author | Verri, Fellippo Ramos [UNESP] | |
dc.contributor.author | Cruz, Ronaldo Silva [UNESP] | |
dc.contributor.author | de Souza Batista, Victor Eduardo [UNESP] | |
dc.contributor.author | Almeida, Daniel Augusto de Faria [UNESP] | |
dc.contributor.author | Verri, Ana Caroline Gonçales [UNESP] | |
dc.contributor.author | Lemos, Cleidiel Aparecido de Araújo [UNESP] | |
dc.contributor.author | Santiago Júnior, Joel Ferreira | |
dc.contributor.author | Pellizzer, Eduardo Piza [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Sacred Heart University | |
dc.date.accessioned | 2018-12-11T17:02:25Z | |
dc.date.available | 2018-12-11T17:02:25Z | |
dc.date.issued | 2016-11-17 | |
dc.description.abstract | The aim of this study was to assess stress/strain of different implant modeling simplifications by 3D-FEA. Three variation of external hexagon implant (à 3.75 à 10 mm) supporting one molar crown were simulated: A (no threads); B (slightly threads simplification); C (original design). 200 N (axial) and 100 N (oblique) were applied. Cortical bone was evaluated by maximum principal stress and microstrain qualitatively and quantitatively (ANOVA and Tukey post hoc (p < 0.05)). Higher stress levels (p < 0.05) were observed in model A. Models B and C presented similar stress transmission. It was possible to conclude that slightly simplification should be used for studies evaluating stress transferring for bone tissue. | en |
dc.description.affiliation | Department of Dental Materials and Prosthodontics Aracatuba Dental School UNESP – Univ Estadual Paulista | |
dc.description.affiliation | Department of Pediatric and Community Dentistry Aracatuba Dental School UNESP – Univ Estadual Paulista | |
dc.description.affiliation | Department of Health Sciences Sacred Heart University | |
dc.description.affiliationUnesp | Department of Dental Materials and Prosthodontics Aracatuba Dental School UNESP – Univ Estadual Paulista | |
dc.description.affiliationUnesp | Department of Pediatric and Community Dentistry Aracatuba Dental School UNESP – Univ Estadual Paulista | |
dc.format.extent | 1665-1672 | |
dc.identifier | http://dx.doi.org/10.1080/10255842.2016.1176156 | |
dc.identifier.citation | Computer Methods in Biomechanics and Biomedical Engineering, v. 19, n. 15, p. 1665-1672, 2016. | |
dc.identifier.doi | 10.1080/10255842.2016.1176156 | |
dc.identifier.file | 2-s2.0-84963877313.pdf | |
dc.identifier.issn | 1476-8259 | |
dc.identifier.issn | 1025-5842 | |
dc.identifier.scopus | 2-s2.0-84963877313 | |
dc.identifier.uri | http://hdl.handle.net/11449/172847 | |
dc.language.iso | eng | |
dc.relation.ispartof | Computer Methods in Biomechanics and Biomedical Engineering | |
dc.relation.ispartofsjr | 0,579 | |
dc.rights.accessRights | Acesso aberto | pt |
dc.source | Scopus | |
dc.subject | biomechanics | |
dc.subject | Dental implants | |
dc.subject | finite element analysis | |
dc.title | Can the modeling for simplification of a dental implant surface affect the accuracy of 3D finite element analysis? | en |
dc.type | Artigo | pt |
dspace.entity.type | Publication | |
relation.isDepartmentOfPublication | 5f53b343-da2a-4737-96ec-6e2389a6d704 | |
relation.isDepartmentOfPublication.latestForDiscovery | 5f53b343-da2a-4737-96ec-6e2389a6d704 | |
relation.isOrgUnitOfPublication | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
relation.isOrgUnitOfPublication.latestForDiscovery | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatuba | pt |
unesp.department | Materiais odontológicos e Prótese - FOA | pt |
unesp.department | Odontologia Infantil e Social - FOA | pt |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- 2-s2.0-84963877313.pdf
- Tamanho:
- 1.59 MB
- Formato:
- Adobe Portable Document Format
- Descrição: