Analysis of the biomechanical behavior of short implants: the photo-elasticity method

Nenhuma Miniatura disponível
Data
2015-10-01
Autores
Pellizzer, Eduardo Piza [UNESP]
Mello, Caroline Cantieri de[UNESP]
Santiago Junior, Joel Ferreira [UNESP]
Souza Batista, Victor Eduardo de [UNESP]
de Faria Almeida, Daniel Augusto [UNESP]
Verri, Fellippo Ramos [UNESP]
Título da Revista
ISSN da Revista
Título de Volume
Editor
Elsevier B. V.
Resumo
The aim of this study was to analyze the stress distribution of short implants supporting single unit or splinted crowns by the photo-elasticity method. Four photo-elastic models were produced: A (3.75×7mm); B (3.75×7mm, 3.75×7mm and 3.75×7mm); C (3.75×10mm, 3.75×7mm and 3.75×7mm); D (3.75×13mm, 3.75×7mm and 3.75×7mm). The prostheses were made with Ni-Cr alloy. A load of 100N in the axial and oblique directions was applied, totaling 380 applications, individually capturing their images in each model. The data were randomized and analyzed qualitatively and quantitatively by 2 examiners. The oblique loading was significantly more damaging. The increase in length was favorable for stress distribution (p<0.05). The splinting was beneficial for the transmission of stresses mainly (p<0.05). The splinting of the crowns, as well as increasing the length of the first implant and axial loading was most beneficial in the stress distribution. Short splinted implants behaved better than single unit implants. Increasing of the length of the first implant significantly improved the stress distribution in all analyzed situations.
Descrição
Palavras-chave
Dental implants, Dental prosthesis, implant-supported, Dental stress analysis
Como citar
Materials Science & Engineering. C, Materials For Biological Applications, v. 55, p. 187-192, 2015.